Cold Plasma High-frequency Beauty Device
Versatile Probe Configuration: Includes two handpieces and eight specialized probes, covering a wide range of treatments—such as facial anti-aging, acne care, and scalp maintenance—to meet the diverse service requirements of professional aesthetic clinics.
Professional-Grade, User-Friendly Operation: Features a 7-inch touchscreen, adjustable energy levels (1–20), and both continuous and single-point operating modes. It supports a wide voltage range and comes with a mobile cart, ensuring simple operation—ideal for small to medium-sized beauty salons.
Description
Technical Parameters
A Room-Temperature Plasma Platform for Acne Care, Skin Repair, and Scalp Treatment
Plasma devices have a reputation problem in some markets. Practitioners associate them with heat, arcing, and a narrow margin between an effective pass and a burn. That association comes from older thermal plasma systems, where the tip gets hot enough to char tissue and the operator's technique has to be very precise.
Cold plasma works differently. The gas is ionized, but the plasma itself stays close to room temperature. What reaches the skin is reactive oxygen and nitrogen species rather than bulk heat. That changes what the device can be used for, who can operate it, and how often a client can be treated. It also means the same platform can be used on the scalp, on inflamed acne, and on skin that would not tolerate a thermal pass.
This unit packages that principle into a two-handle console with eight interchangeable probes. It is aimed at small and mid-sized clinics that want to add a plasma service line without committing to a large capital purchase or a long training curve.
Product Introduction: Core Function and Technical Explanation
The console applies voltage across an argon gas stream inside the handpiece. The gas ionizes into plasma, and the electrons carry high energy while the overall temperature of the plasma plume stays near ambient. When the plume meets skin, it delivers reactive oxygen species, free radicals, and UV in trace amounts. Those reactive species interact with the surface layer and with cells just beneath it.
Four clinical effects follow from that interaction, and each maps to a different probe or protocol.
Antimicrobial and anti-inflammatory action. Reactive oxygen species disrupt bacterial cell membranes. On inflammatory acne, this reduces the bacterial load that drives the inflammatory cycle. The same mechanism applies to seborrheic dermatitis and other surface inflammatory conditions.
Fibroblast stimulation. Controlled plasma exposure triggers a repair response in the dermis, which increases collagen and elastin production over the following weeks. This is the basis for the anti-aging and firming protocols.
Transdermal delivery support. Plasma temporarily alters the barrier properties of the stratum corneum. Serums applied immediately after a pass penetrate more effectively than they would on intact skin. Clinics that retail topical products use this to make the product feel like part of the treatment rather than an afterthought.
Wound and lesion management. The direct-stream nozzle concentrates plasma on a small target. In professional hands, this is used for skin infections, chronic wounds, and stubborn lesions. This is the most technique-sensitive application and should be reserved for trained operators.
The hardware is deliberately simple. A 7-inch touchscreen runs the interface. Two handpieces (A and B) allow the operator to keep two probe types mounted during a single session, which matters when a protocol moves from a broad anti-aging pass to a targeted spot treatment. Eight probes cover the range from square tube to 44-pin needle to direct nozzle. Energy is adjustable across twenty levels, with continuous and single-point delivery modes. A foot pedal controls activation so the operator's hands stay on the handpiece.
The unit runs on 110–220V wide voltage. That is a practical detail for distributors and for clinics in markets where supply fluctuates; there is no need for a separate transformer, and one stock configuration serves multiple regions. The trolley has a storage drawer and locking casters.
One operational note that belongs in the introduction rather than buried in the manual: the handpieces require an argon gas supply. Argon consumption varies with use, and clinics should confirm the cylinder arrangement, regulator compatibility, and local refill availability with the supplier before committing to a service launch. This is the single most common oversight when clinics add a plasma device.

Product Advantages
Room-temperature operation reduces technique risk. Because the plasma plume is not thermally ablative, the margin for error is wider than with thermal plasma or radiofrequency. Operators can work closer to the skin and hold a position slightly longer without the burn risk that makes thermal devices unforgiving.
Two handpieces, eight probes, one console. The A and B handpieces let the operator switch between probe types without breaking the treatment flow. A facial protocol can move from square tube to roller to 44-pin needle in a single session without remounting hardware.
Twenty energy levels with continuous and single-point modes. Low levels suit sensitive skin and first sessions. Higher levels suit scalp work and targeted lesion treatment. Continuous mode covers broad areas; single-point mode concentrates on a specific spot.
An unusually broad indication list for the price point. Acne and seborrheic dermatitis, anti-aging and firming, product penetration, wound and lesion management, and scalp and hair follicle care all run on the same unit. That breadth matters for salons where a single-service device would sit idle.
Scalp treatment is a genuine revenue line, not a footnote. The trumpet tube head and the roller heads are specified for follicle stimulation and scalp conditioning. Hair loss consultations are a growing category in most markets, and this gives clinics a non-invasive entry point.
Wide-voltage input simplifies distribution. One 110–220V configuration covers most markets. Distributors do not need to stock separate voltage variants, which reduces inventory complexity.
Interface language can be customized. For OEM buyers and for distributors serving non-English markets, the touchscreen language can be adapted. This is a small detail that makes the device feel locally specified rather than imported.
Mobile trolley with storage. The unit sits on a locking-caster trolley with a drawer for probes, gels, and consumables. In a salon where treatment rooms are shared, mobility matters more than a fixed installation.
Low barrier to staff training. The workflow is linear: select handpiece, select probe, set time and energy, start. New staff can run a basic protocol after a short session, and the more technique-sensitive applications can be reserved for senior operators.
Technical Specifications
| Parameter | Specification |
|---|---|
| Power frequency | 50Hz |
| Input voltage | 110–220V wide voltage |
| Rated power | 400W |
| Energy levels | 1–20, start from low |
| Display | 7-inch touchscreen |
| Interface language | Customizable |
| Handpieces | A handle and B handle, both included |
| Probes | 8 interchangeable |
| Delivery modes | Continuous, single-point |
| Control | Foot pedal and touchscreen |
| Packaging dimensions | 55 × 42 × 37 cm |
| Gross weight | 13.1 kg |
| Included accessories | A handle ×1, B handle ×1, 8 probes, foot pedal ×1, power cable ×1 |
| Structure | Front: 7-inch display, A and B handpiece ports. Rear: ventilation, power inlet, foot pedal port, power switch |
| Mounting | Trolley with storage drawer and locking casters |
| Gas requirement | Argon supply required for handpiece operation |
Probe Guide
| Probe | Session Time | Primary Effect | Typical User | Operator Note |
|---|---|---|---|---|
| Square tube head | 5–10 min | Fine line softening, texture improvement, product penetration | Anti-aging, general skin quality | Work close to the skin; keep the head moving |
| Trumpet tube head | 5–7 min | Follicle stimulation, hair growth support | Scalp care, hair thinning | Light pressure, slow movement, no stationary holding |
| Roller heads (large and small) | 3–8 min | Epidermal turnover, smoothing, firming | Rough or uneven texture | Continuous gentle motion; adjust time to tolerance |
| 44-pin needle head | 5–10 min | Dermal collagen and elastin stimulation | Laxity, anti-aging | Control pressure and speed; avoid over-stimulation |
| Ceramic head | 5–10 min | Antimicrobial, anti-inflammatory | Inflammatory acne, seborrheic dermatitis | Hover near the skin without contact; watch for sensitivity |
| Diamond-shaped head | 5–10 min | Elasticity and firming, perioral and periorbital laxity | Lifting and tightening | Smooth gliding passes over face and neck |
| Stream direct nozzle | 15 min | Infection management, wound repair | Professional clinical use only | Trained operators only; strict asepsis; precise targeting |



Use Scenarios: Where This Device Fits
Small and mid-sized beauty salons. The economics here are straightforward. A salon that adds plasma facials, acne protocols, and scalp treatments from one unit can schedule the device across more clients per week than a single-service machine allows. The trolley format means it can move between rooms rather than occupying a dedicated treatment space.
Acne-focused clinics. Inflammatory acne and seborrheic dermatitis respond to the antimicrobial and anti-inflammatory action without the irritation that some topical and energy-based treatments cause. The ceramic head is the workhorse probe for this patient group.
Anti-aging and skin-quality practices. The 44-pin needle head and diamond-shaped head support collagen stimulation and firming protocols. Because the treatment is non-thermal and non-invasive, it can be scheduled more frequently than ablative or thermal alternatives and combined with other modalities in the same visit.
Scalp and hair care clinics. The trumpet tube head is specified for follicle stimulation. For clinics building a hair health service line, this provides a non-invasive option alongside mesotherapy or low-level laser therapy.
Clinics offering post-treatment support. Plasma's barrier-modulating effect makes it useful before topical serum application. Practices that retail corrective skincare can build a treatment-plus-product protocol around a single session, which raises the value of each appointment.
Conditions and services commonly addressed:
Inflammatory acne and post-acne redness
Seborrheic dermatitis and surface inflammatory conditions
Fine lines, laxity, and general skin firmness
Uneven tone and dullness
Product penetration and serum absorption
Scalp conditioning and follicle stimulation
Targeted lesion and infection management (trained operators)
Wound and post-procedure repair support (trained operators)
Cold plasma is a supportive and aesthetic modality. Clinics should confirm local regulatory classification and advertising rules before making therapeutic claims, particularly for infection and wound applications.
Treatment Comparison: What Clients Should Expect
Plasma treatments produce visible change gradually rather than dramatically. That is worth stating plainly during consultation, because clients who expect a same-day transformation are the ones who leave dissatisfied.
During the session. Most clients describe a faint tingling, a slight ozone smell, and occasional warmth. There is no numbing required for facial protocols. The square tube and roller passes feel lighter than the 44-pin needle head, which produces a more noticeable prickling sensation. Scalp treatment with the trumpet head is generally well tolerated.
Immediately after. Mild redness is normal and usually settles within a few hours. Skin often feels tighter and looks brighter, partly from the plasma effect and partly from the serum applied afterward. Clients should avoid makeup for several hours to allow the barrier to settle.
Over the first week. Acne lesions typically calm and reduce in inflammation. Seborrheic areas become less reactive. For anti-aging protocols, the immediate firmness fades slightly and then returns progressively as collagen response builds.
Over a series. Most clinics schedule an initial course of four to six sessions at one- to two-week intervals, followed by monthly maintenance. Firmness, tone, and texture improve cumulatively. Scalp protocols generally require a longer commitment - three months or more - before clients notice reduced shedding or visible density change, and expectations should be set accordingly.
Compared with thermal plasma and radiofrequency. Thermal plasma and fractional RF rely on heat. They can deliver stronger immediate tightening but come with downtime, pigmentation risk on darker skin, and a narrower safety margin. Cold plasma trades some of that immediate intensity for repeatability, comfort, and suitability across a wider range of skin types and conditions. Many clinics run both, using cold plasma for maintenance and sensitive-skin clients, and thermal options for patients seeking maximum tightening.
Compared with topical acne treatment alone. Topical regimens depend on daily adherence, which many clients struggle with. A clinic-based plasma protocol gives the practitioner direct control over delivery and pairs well with a simplified home routine.
Customer Feedback and Cooperation Cases
A dermatology-adjacent skin clinic in Poland added the unit primarily for inflammatory acne and seborrheic dermatitis. The lead practitioner reported that clients who could not tolerate acids or retinoids responded well to the ceramic head protocol, and that the absence of peeling made it easier to schedule sessions during working weeks. The clinic now runs the device four days a week.
A hair and scalp studio in the United Kingdom uses the trumpet tube head alongside low-level laser therapy. The owner noted that clients value having a non-injection option in the hair health menu, and that the two-handle setup allows a scalp pass and a facial pass in the same appointment for clients booking combined sessions.
A beauty salon in Malaysia built a plasma facial package around the square tube and roller heads, positioning product penetration as the headline benefit. The owner said retail serum sales rose after staff began applying product immediately post-treatment and explaining why absorption differs at that moment.
A distributor in Eastern Europe ordered a batch under its own brand with a localized interface. The distributor cited the wide-voltage input and customizable language as the two factors that made one stock configuration viable across several countries, and noted that the argon supply requirement was the main pre-sale question raised by end customers.


Factory Strength and Certifications
The production base behind this device operates a facility of significant scale dedicated to professional aesthetic equipment, with ISO 13485 medical device quality management and ISO 9001 certification in place. Documented inspection procedures and operating specifications are followed at each production stage, and certificate copies can be provided during the inquiry process.
Benomi, as the export partner for this line, brings more than 18 years of experience in professional aesthetic equipment. The company operates an international-standard dust-free production workshop - a specification that requires substantial investment in air filtration and environmental control and is uncommon in this segment. Benomi holds ISO, CE, and FDA certifications across its product range.
OEM and ODM development is supported. Custom logo, interface language, packaging branding, and probe configuration can be adapted. Qualified orders receive a free logo design service, and the engineering team handles region-specific requirements including language packs and voltage confirmation.
Each unit is tested before shipment with video documentation provided. Installation guidance and operator training are handled remotely. The modular architecture simplifies diagnosis and probe replacement, which matters in clinics where the device is booked most days of the week. Engineers respond within 24 hours, spare parts are free during the warranty period, and the warranty runs for two years with lifelong maintenance support afterward.
Wholesale Policy
| Item | Policy |
|---|---|
| Minimum order | One unit for evaluation; tiered distributor pricing from five units |
| OEM and ODM | Available. Custom logo, interface language, packaging, and probe configuration. Free logo design for qualified orders. |
| Production time | 7–12 working days for standard configuration; 15–20 working days for customized builds |
| Shipping | Express couriers for single units; air or sea freight for volume orders |
| Payment | T/T, Western Union, or negotiated terms for established distributors |
| Packaging | Reinforced carton, 55 × 42 × 37 cm, gross weight 13.1 kg |
| Warranty | Two years, with lifelong maintenance support |
| After-sales | 24-hour engineer response; free spare parts during warranty; remote training and commissioning |
| Documentation | User manual, probe guide, certification copies, and test report supplied with each unit |


Frequently Asked Questions
Q: What exactly makes this "cold" plasma rather than thermal plasma?
A: The argon gas is ionized, but the plasma plume stays near room temperature. There is no bulk heat delivered to the tissue. The clinical effect comes from reactive oxygen species rather than thermal ablation, which is why there is no charring, no scabbing, and a much shorter recovery period.
Q: Does the device need a gas supply?
A: Yes. The handpieces ionize argon, so a gas cylinder and regulator are required. This is the detail buyers most often overlook. Confirm the cylinder arrangement, regulator compatibility, and local refill availability with us at quotation stage so the service can launch without interruption.
Q: Which probe should a clinic start with?
A: For acne and inflammation, the ceramic head. For general anti-aging and texture, the square tube head plus roller heads. For scalp work, the trumpet tube head. The 44-pin needle head and stream direct nozzle are better suited to trained operators and should be introduced once staff are comfortable with the basic workflow.
Q: How many sessions does a client need?
A: Facial protocols typically start with four to six sessions at one- to two-week intervals, then move to monthly maintenance. Scalp protocols generally need three months or more before clients notice reduced shedding or visible density change. Setting that expectation at consultation prevents most dissatisfaction.
Q: Is there downtime?
A: Minimal. Mild redness usually settles within hours. Clients should avoid makeup for several hours after treatment and should use barrier-repair products with antioxidants, hyaluronic acid, or ceramides. Daily sun protection is essential.
Q: Can it be used on darker skin types?
A: Because the mechanism is non-thermal and does not target melanin, cold plasma does not carry the same pigmentation risk as thermal or light-based treatments. Conservative energy settings and a test pass remain good practice for any skin type.
Q: Who should not be treated?
A: Clients with broken or open skin, active severe skin disease, known hypersensitivity, pregnancy or breastfeeding, recent laser or chemical peel treatment, immunosuppression, or implanted electronic devices such as pacemakers. Clinics should maintain a written contraindication checklist and screen every client before the first session.
Q: How is the device maintained?
A: Probes should be cleaned and disinfected between clients according to the manufacturer's instructions. The handpiece and cable should be inspected for damage. Gas lines and regulators should be checked periodically. The unit itself requires no water management or filter replacement, which keeps maintenance simple.
Q: What voltage does it require?
A: The input is 110–220V wide voltage at 50Hz, 400W. One configuration serves most markets, which simplifies distributor inventory.
Q: Can the interface language and branding be customized?
A: Yes. Interface language, logo, packaging, and probe configuration can all be adapted through OEM and ODM arrangements. Qualified orders receive a free logo design service.
Q: What is the minimum order and lead time?
A: One unit for evaluation, with distributor pricing from five units. Standard production takes 7–12 working days; customized builds take 15–20 working days. Shipping time depends on destination and freight method.
Q: How do I request a quotation?
A: Send us a message with your country, clinic type, the services you plan to offer, and whether you need a localized interface or custom branding. We will reply within one business day with pricing, freight estimates, certification documents, and a video showing the probe workflow in operation.
Request Pricing and a Probe Demonstration
Tell us which services you plan to launch - acne care, anti-aging, scalp treatment, or a combination - and we will send a full quotation, the argon supply requirements for your region, certification copies, and a short video demonstrating the probe changeover and treatment workflow.
Weifang Benomi Electronic Technology Co., Ltd.
Weifang, Shandong, China
More than 18 years in professional aesthetic equipment
[Send Inquiry] - Include your country, intended applications, and target quantity for the fastest response.
Hot Tags: cold plasma high-frequency beauty device, China cold plasma high-frequency beauty device manufacturers, factory
Previous
No InformationSend Inquiry














