Dual-Source Piezoelectric Focused Shockwave System
video

Dual-Source Piezoelectric Focused Shockwave System

Precision coverage with dual applicators: Point-focus applicator (for deep, localized lesions) and curved linear applicator (for large, superficial areas)—a single device meeting needs ranging from targeted pain points to soft-tissue treatment.
Piezoelectric focusing with gel pad depth adjustment: Stable, fixed focal point; 12 gel pads (5–40 mm) allow for precise control of penetration depth, ensuring accurate targeting and minimal tissue damage.
Patented pulse modes and long service life: Dual modes (T-BURST and T-RAMP) expand dynamic treatment capabilities; applicators feature a lifespan of up to 5 million pulses, and built-in preset protocols ensure ease of operation.
Send Inquiry

Description

Technical Parameters

Product Overview
The Dual-Source Piezoelectric Focused Shockwave System from Benomi is a professional extracorporeal shockwave therapy (ESWT) platform built around direct piezoelectric focusing. Instead of using a reflector cup to concentrate acoustic energy, the device positions piezoelectric ceramic elements on a concave base. When high-voltage pulses excite these elements, they expand at micrometer scale and generate pressure waves that converge precisely on a target point. Because there is no reflector, the handpiece stays compact, treatment noise remains low, and the focal volume does not shift or expand when the operator changes energy settings. The result is predictable energy delivery at a chosen depth.

The system includes two interchangeable applicators. A round focused head creates a small, precise focal zone for localized conditions such as calcific deposits, deep trigger points, and Peyronie's plaques. A curved linear head produces a long, broad focal area for larger soft tissue regions, including the plantar fascia, Achilles tendon, and the corpora cavernosa in erectile dysfunction therapy. Interchangeable gel pads act as acoustic spacers, allowing penetration depth to be adjusted in 5 mm increments from 5 mm to 40 mm. This mechanical depth control reduces scattering and keeps the focal point exactly where the clinician intends.

The console runs up to 10 Hz, but its design emphasis is on accurate energy output rather than speed alone. Each treatment head is rated for up to 5 million pulses. The interface includes preset body-region protocols that suggest starting parameters, while still allowing full manual adjustment. The machine ships with two handpieces in a single package, so a clinic can treat both small, deep lesions and broad, superficial areas without changing devices.

1

Key Advantages

Dual-Source Design Covers Focal and Linear Treatment Needs
The round focused head delivers a focal zone of approximately 10 × 2.5 × 2.5 mm with a maximum penetration depth of 40 mm and an energy flux density up to 0.82 mJ/mm². The curved linear head covers a zone of about 50 × 20 × 5 mm with a maximum depth of 20 mm and an energy flux density up to 0.17 mJ/mm². One console therefore handles both high-precision and wide-area protocols, from calcific tendinopathy to large myofascial regions.

Direct Piezoelectric Focusing Maintains a Stable Focal Volume
Unlike electromagnetic or radial devices where focal characteristics can change with power, the piezoelectric array keeps the focal geometry constant across energy levels. Clinicians can raise or lower output without worrying that the treatment zone will drift or broaden unexpectedly.

Precise Depth Control Through Replaceable Gel Pads
Gel pads are available in 5 mm steps. The round head accepts eight pad sizes from 5 mm to 40 mm; the linear head accepts four sizes from 5 mm to 20 mm. Switching a pad moves the acoustic focus deeper or shallower without changing the handpiece. The pads also reduce wave scattering and help maintain consistent coupling with the skin.

Patented T-Mode Pulse Patterns for Specialized Protocols
Two proprietary modes expand treatment options. T-BURST delivers a cluster of pulses followed by a pause, allowing tissue to receive mechanical stimulation and then recover. T-RAMP gradually increases frequency from a low starting value to a target over a set time, which is useful for tendon and muscle-tendon junction work. Both modes support the concept of mechanotransduction: converting mechanical stress into biological repair signals.

Broad Clinical Coverage Across MSK, Urology, and Dermatology
The device treats muscle and tendon injuries, joint pain, bone nonunion, plantar fasciitis, and myofascial trigger points. It also supports erectile dysfunction therapy through linear focused energy along the penile shaft and crura, and Peyronie's disease through precise calcification targeting with the round head. Chronic skin ulcers can benefit from the same acoustic stimulation.

Long Service Life and Low Maintenance
Each handpiece is rated for up to 5 million pulses. The piezoelectric crystals do not require the same frequent replacement as some electromagnetic coils or pneumatic projectiles. Routine care is limited to cleaning the applicator surface, checking the gel pads, and applying fresh coupling gel. This keeps long-term operating costs predictable.

Preset Protocols With Manual Override
Built-in body-region presets recommend treatment parameters for common conditions. New staff can start treating quickly, while experienced clinicians retain full control over energy, frequency, and pulse mode. The touchscreen interface is straightforward and does not require extensive training.

 

Technical Specifications

Parameter Detail
Technology Direct piezoelectric focused shockwave
Applicators Round focused head, curved linear head
Round Head Focal Size Approx. 10 × 2.5 × 2.5 mm
Round Head Max Penetration 40 mm
Round Head Max EFD 0.82 mJ/mm²
Round Head Gel Pads 5, 10, 15, 20, 25, 30, 35, 40 mm (8 sizes)
Linear Head Focal Size Approx. 50 × 20 × 5 mm
Linear Head Max Penetration 20 mm
Linear Head Max EFD 0.17 mJ/mm²
Linear Head Gel Pads 5, 10, 15, 20 mm (4 sizes)
Frequency Up to 10 Hz
Pulse Lifespan Up to 5 million pulses per handpiece
Operating Modes Standard, T-BURST, T-RAMP
Display Touchscreen with preset protocols and manual mode
Power Supply 100–240 V AC, 50/60 Hz
Packaging Dimensions 42 × 27 × 62 cm
Gross Weight Approx. 37 kg
Certifications ISO 13485, CE, FDA
Warranty 2 years

04

02

03

Ideal Settings

Orthopedic and sports medicine clinics treating tendinopathies, plantar fasciitis, calcific shoulder deposits, and myofascial pain.

Urology and men's health centers offering shockwave therapy for erectile dysfunction, Peyronie's disease, and chronic pelvic pain.

Rehabilitation hospitals managing bone nonunion, post-surgical stiffness, and soft tissue fibrosis.

Dermatology and wound care units applying acoustic stimulation to chronic ulcers and slow-healing wounds.

Multidisciplinary pain clinics that need both focal and broad-area treatment capability in a single machine.

Physiotherapy practices seeking an upgrade from radial pressure wave devices to true focused shockwave technology.

 

Treatment Comparison

Case A: Calcific Rotator Cuff Tendinopathy
A 54-year-old female presented with a 1.0 cm calcification in the supraspinatus tendon and limited shoulder abduction. The clinician used the round focused head with a 20 mm gel pad at an energy setting of 0.35 mJ/mm², delivering 2,500 pulses per session for three sessions at weekly intervals. Follow-up radiographs at six weeks showed near-complete resorption of the calcium deposit. Active abduction improved from 75 degrees to 150 degrees, and pain scores dropped from 7/10 to 1/10.

Case B: Erectile Dysfunction
A 58-year-old male with mild vasculogenic ED completed a protocol using the curved linear head with a 10 mm gel pad. The clinician treated both corpora cavernosa and both crura, delivering 2,000 pulses per side at 0.160 mJ/mm² and 6 Hz. Sessions were conducted weekly for four weeks. By the end of the course, the patient reported improved erectile function and a higher IIEF-5 score. No adverse effects were noted.

Case C: Chronic Plantar Fasciitis
A 46-year-old female runner with twelve months of heel pain received four sessions using the linear head at 0.17 mJ/mm² and 8 Hz, with the gel pad set to 15 mm. Morning pain decreased from 8/10 to 2/10 by the third session. The patient returned to running gradually and remained symptom-free at six-month follow-up.

Case D: Myofascial Trigger Points in the Upper Back
A 38-year-old male office worker with chronic trapezius trigger points underwent five sessions using the round head at a shallow depth of 10 mm and moderate energy. Each session took under ten minutes. The patient reported immediate soreness relief after the first treatment, and after the full course, the trigger points were no longer palpable.

 

Practitioner Feedback
"We replaced two separate shockwave machines with the Benomi dual-source system. The round head handles our calcific tendon cases with precision, while the linear head covers plantar fasciitis and ED protocols. The gel pad system makes depth adjustment simple and reproducible. Patients report less discomfort compared to our old pneumatic device."
- Dr. Elena M., Sports Medicine Physician, Barcelona

"The T-RAMP mode has become my standard for Achilles tendinopathy. The gradual frequency increase feels more physiological, and patients seem to tolerate it better. The built-in presets are accurate enough for new staff, but I still have full manual control when I need it."
- Marco V., Physiotherapist, Milan

"We added shockwave therapy for erectile dysfunction six months ago. The linear applicator covers the penile shaft and crura efficiently, and the treatment takes about fifteen minutes. Patients appreciate that it is non-invasive and drug-free. The machine paid for itself within the first quarter."
- Dr. Alan S., Urologist, Boston

08

05

06

 

 

Manufacturing and Certifications
Weifang Benomi Electronic Technology Co., Ltd. has specialized in professional medical and aesthetic equipment for over 18 years. The company operates from ISO-classified dust-free workshops in Weifang, China. Each Dual-Source Piezoelectric Focused Shockwave System is assembled and calibrated under strict quality controls. The piezoelectric arrays are tested for output consistency, and the treatment heads undergo a full pulse test before packing.

The device carries ISO 13485, CE, and FDA certifications. Benomi supports international clients with OEM and ODM customization, including logo placement on the console and handpieces, software interface branding, and custom packaging. A 24-hour online after-sales team provides technical support, and modular components allow quick replacement if service is needed.

 

Wholesale Policies and Customization Support

Minimum Order Quantity: A single evaluation unit is available for clinical testing. Wholesale pricing starts at five units.

OEM/ODM Customization: Branding on the machine body, touchscreen interface, and treatment heads. Custom gel pad packaging and color options are available. Free logo design assistance is included at the quotation stage.

Packaging: Export-grade protective carton with foam inserts. Custom flight cases are available for volume orders.

Lead Times: In-stock sample units ship within 3 business days. Branded batch orders typically ship within 7 to 18 business days, depending on customization depth.

Warranty: 2-year comprehensive warranty on the main unit and treatment heads. Gel pads are consumable accessories and are not covered under warranty.

After-Sales Service: A 24-hour online support team handles troubleshooting via email, video call, or remote diagnostics. Warranty-covered spare parts are dispatched immediately at no cost.

Training: A remote onboarding session and a video training library are provided with the first order. On-site training can be arranged for larger purchases.

2661--2

2661-

Frequently Asked Questions

What makes piezoelectric focused shockwave different from radial pressure wave devices?
Radial devices produce a wave that spreads across the skin surface and loses energy quickly. Piezoelectric focused shockwave concentrates acoustic energy at a defined depth inside the tissue, which is essential for treating deep structures such as tendons, bone, or erectile tissue. The focal zone remains stable even when energy settings change.

How do I choose between the round and linear heads?
The round head is best for small, localized targets such as calcifications, deep trigger points, and Peyronie's plaques. The linear head covers larger areas like the plantar fascia, Achilles tendon, and penile shaft. Many clinicians use both during the same treatment session depending on the condition.

What is the purpose of the gel pads?
Gel pads act as spacers between the handpiece and the skin. By selecting a thicker or thinner pad, you shift the focal point deeper or shallower. This allows you to match the acoustic focus to the exact depth of the lesion without changing the energy output or handpiece angle.

Is the treatment painful?
Most patients feel a light tapping or pulsing sensation. The piezoelectric design produces less noise and less superficial discomfort than older electromagnetic or pneumatic systems. Anesthesia is rarely required.

How many sessions are needed?
The number depends on the condition. Tendinopathies and soft tissue injuries typically require three to six sessions at weekly intervals. ED protocols often involve four to six weekly sessions. Peyronie's disease may need six to eight sessions. Your clinician will recommend a plan after an initial assessment.

Can this device treat erectile dysfunction?
Yes. The linear head is used to deliver focused shockwaves along the corpora cavernosa and crura. This stimulates angiogenesis and improves blood flow. The treatment is non-invasive, takes about fifteen minutes, and does not require anesthesia or downtime.

Are the gel pads reusable?
Yes, the gel pads are reusable. They should be cleaned after each session and inspected for damage. Replace them when the surface becomes worn or if air bubbles are trapped between the pad and the handpiece. Benomi supplies replacement pads in all sizes.

How do I request a quotation or become a distributor?
Complete the inquiry form on this page with your clinic or company name, country, and whether you need a sample evaluation unit, standard wholesale pricing, or OEM branding. A product specialist will respond within one business day with a tailored proposal, current lead time, and any additional documentation you require. Your contact information is kept strictly confidential.

Hot Tags: dual-source piezoelectric focused shockwave system, China dual-source piezoelectric focused shockwave system manufacturers, factory

Send Inquiry