Indiba Deep Fever Master
video

Indiba Deep Fever Master

Dual-technology synergy: RES high-frequency deep heat (for internal fat burning and detoxification) and CAP radiofrequency heat (for external skin tightening and anti-aging) work simultaneously from the inside out.
Multi-functional in one unit: Achieves over ten effects in a single device, including fat reduction and body shaping, lymphatic drainage, skin tightening and brightening, wrinkle improvement, and postpartum repair.
Flexible probe switching: Equipped with dedicated probes such as the RES fat-dissolving head and the CET radiofrequency head, allowing for quick and precise treatment of different areas.
Send Inquiry

Description

Technical Parameters

indiba 2

Product Introduction – Core Functions & Technical Overview

The Indiba Deep Fever Master by Benomi is a radiofrequency (RF) therapy platform that uses 448 kHz capacitive and resistive electric transfer (CRET) to deliver targeted deep tissue heating for both aesthetic and therapeutic purposes. The system is built around two complementary energy delivery modes-CAP (Capacitive) and RES (Resistive)-each designed to interact with different tissue types at different depths.

In CAP mode, the active electrode creates a superficial electric field that concentrates energy in tissues with high water and electrolyte content, such as the skin, superficial muscles, and the vascular/lymphatic network. The treatment head remains at a constant cool temperature on the surface, while RF energy penetrates to the dermis and hypodermis, generating controlled heat of 45–60 °C. This stimulates an immediate contraction of collagen fibres and triggers fibroblast activity, leading to new collagen synthesis over time.

In RES mode, the current passes through the body between an active electrode and a neutral plate, meeting higher resistance in deep, dense tissues-including visceral fat, deep muscle, tendons, and joints. The friction of charged particles under this high-frequency field produces deep endogenous heat. This thermal effect accelerates local metabolism, promotes the breakdown of adipocytes into free fatty acids and glycerol, and supports lymphatic and venous drainage.

The console is supplied with four quick-switch probes, including a ceramic CAP probe for facial and superficial work, and a dedicated RES deep-heat head for body contouring. Practitioners can move between modalities in seconds, tailoring the session to the client's specific concerns without interrupting the treatment flow.

 

Key Advantages at a Glance

Dual-Mode 448 kHz Technology – The combination of CAP and RES allows clinicians to treat surface laxity, deep fat deposits, and musculoskeletal discomfort from a single device.

Surface-Safe CAP Treatment – The capacitive method keeps the epidermis at a comfortable temperature while heating the dermis, making it suitable even for sensitive or thin-skinned areas.

Deep Visceral & Fascial Heating with RES – Resistive mode channels energy into high-resistance tissues, supporting the reduction of stubborn visceral fat, improving joint mobility, and accelerating recovery from muscle stiffness.

Collagen Remodelling & Skin Tightening – Thermal stimulation of the dermis (45–60 °C) triggers immediate collagen contraction and long-term neocollagenesis, resulting in firmer, more elastic skin.

Lymphatic Drainage & Detoxification – The deep heating effect raises local blood circulation and lymphatic flow, helping to clear metabolic waste and reduce fluid retention.

Four Interchangeable Probes – The system includes a ceramic CAP probe for face and neck, a RES body head for larger areas, and additional probes for targeted treatment, all of which can be switched rapidly during a session.

Non-Invasive with No Downtime – The treatment is non-surgical and requires no anaesthesia. Clients can return to normal activities immediately.

 

Technical Specifications

Specification Detail
Technology 448 kHz Capacitive (CAP) & Resistive (RES) RF
Operating Modes CAP (Superficial), RES (Deep)
Frequency 448 kHz
Maximum Output Power Up to 200 W (RES mode)
Probes Included 4 Quick-Switch Handpieces (Ceramic CAP, RES Body Head, etc.)
Electrode Type Capacitive (Coated Ceramic) / Resistive (Active + Neutral Plate)
Treatment Temperature 45–60 °C (Dermis) in CAP mode
User Interface Digital Touch Panel with Protocol Presets
Cooling Integrated Thermal Monitoring & Ventilation
Power Supply AC 100–240V, 50/60 Hz
Net Weight Approx. 10 kg

1 1

1 2

1 3-

Where This Device Is Used

Medical Spas & Aesthetic Clinics – For non-surgical face and neck lifting, wrinkle reduction, and overall skin rejuvenation.

Body Contouring Centres – As a core technology for reducing localised fat, smoothing cellulite, and improving skin laxity on the abdomen, thighs, and arms.

Physiotherapy & Rehabilitation Practices – For pain management, joint stiffness relief, muscle tension release, and post-injury recovery.

Wellness & Detox Clinics – To stimulate lymphatic drainage and improve metabolic function in clients with sluggish circulation or fluid retention.

Postnatal Care Facilities – To help restore abdominal muscle tone, tighten postpartum skin laxity, and support pelvic floor recovery when combined with appropriate exercise.

 

Treatment Comparison – Observed Changes

Concern / Area Pre-Treatment Condition After 6–10 Sessions (Typical Results)
Facial Laxity & Fine Lines Noticeable nasolabial folds, reduced skin bounce, dull complexion. Visible lifting and tightening; improved skin luminosity and smoother texture.
Abdominal Sagging & Stubborn Fat Loose skin and soft tissue around the navel; pinchable subcutaneous fat. Firmer abdominal contour; measurable reduction in waist circumference (2–5 cm).
Post-Pregnancy Belly Diastasis-related laxity and crepey skin. Tighter skin tone and improved muscle definition when combined with core exercises.
Cellulite (Thighs & Buttocks) Dimpled, uneven skin surface. Smoother appearance; reduction in fluid retention and visible orange-peel texture.
Joint Stiffness & Muscle Pain Localised discomfort, reduced range of motion. Temporary pain relief and increased mobility; useful as part of a broader rehabilitation plan.

Individual results depend on age, lifestyle, baseline condition, and adherence to the recommended protocol (typically 1–2 sessions per week for 6–10 weeks).

 

Practitioner Feedback & Clinic Insights

Aesthetic Doctor, Madrid"The Indiba Deep Fever Master lets me treat both skin laxity and deep fat in the same session. I start with CAP on the face to lift the jowls and smooth crow's feet, then switch to RES on the abdomen for visceral heating. Clients love the warm, soothing sensation and see a visible difference after three sessions."

Spa Manager, Dubai"We added this device to our slimming packages six months ago, and it has become one of our most-booked treatments. The four interchangeable probes make it easy to go from face to body without losing time. The deep heating effect feels very luxurious, and we've had excellent feedback about post-treatment skin glow."

Physiotherapist, Rome"I use the RES mode for patients with chronic low back pain and stiff shoulders. The deep warmth reduces muscle guarding and improves local circulation. It's a valuable complement to manual therapy and exercise, and patients report feeling more relaxed and mobile after each session."

1 7

1 4

1 5-

1 6

About the Manufacturer – Benomi

Weifang Benomi Electronic Technology Co., Ltd. has been dedicated to the R&D, manufacturing, and after-sales service of professional aesthetic and therapeutic equipment for over 18 years. Headquartered in Weifang, China, the company operates a dust-free production workshop to protect sensitive electronic components.

OEM/ODM Capabilities – Benomi offers free logo design and branding integration on the device console, startup screen, and packaging. Custom language packages and interface modifications are available for qualified orders.

Certifications – The Indiba Deep Fever Master is manufactured under an ISO 13485 quality management system. The product holds CE certification, and documentation supports FDA listing requirements.

Warranty & Support – A 2-Year Warranty covers manufacturing defects. Technical questions are answered within 24 hours, and online training is provided for all new users.

 

Wholesale Information & Distribution Terms

Minimum Order Quantity (MOQ)One (1) Unit. Sample orders are accepted so distributors can evaluate the device's build quality, probe ergonomics, and heating performance.

Customisation Options

Branding – Logo on the touch panel and device body.

Software – Language localisation and pre-set protocol adjustments.

Colour & Finish – Alternative chassis colours with minimum batch order.

Shipping & Lead Times

Standard Configuration – Dispatched within 3 to 5 business days.

OEM / Custom Orders – Allow 7 to 15 business days for branding and final inspection.

Logistics – Air express (DHL, FedEx, UPS) or sea freight. Benomi provides pre-shipment testing documentation and export assistance.

benomi 23

product-1060-715

Frequently Asked Questions

Q: What is the difference between CAP and RES modes?
A: CAP mode treats superficial tissues such as the skin and upper muscle layers by creating a gentle electric field. It is used for facial rejuvenation, wrinkle reduction, and skin tightening. RES mode passes current deeper into the body to reach tissues with higher resistance, such as visceral fat, deep muscles, and joints. It is used for body contouring, pain relief, and improving deep circulation.

Q: Is the treatment hot or uncomfortable?
A: During CAP treatments, the skin surface stays cool while a pleasant deep warmth builds gradually inside. RES treatments feel like a warm deep-tissue massage. The practitioner adjusts the power based on the client's thermal feedback, so the experience should be relaxing, not painful.

Q: How many sessions are needed to see results?
A: For facial lifting and skin texture improvement, visible changes are often reported after 3–4 sessions. For body contouring and fat reduction, a course of 6–10 sessions (once or twice a week) is generally recommended. Maintenance every 2–4 weeks helps sustain the outcomes.

Q: Are there any contraindications?
A: Yes. Treatment should be avoided during pregnancy, in patients with pacemakers or metal implants near the treatment site, active cancer, acute infections, or thrombophlebitis. A thorough health screening is mandatory before the first session.

Q: Can I combine this therapy with other treatments?
A: Absolutely. The Indiba Deep Fever Master is frequently used as a complement to manual massage, pressotherapy, or cryolipolysis. The deep heating also enhances the absorption of topical serums and slimming creams applied immediately after CAP treatment.

Hot Tags: indiba deep fever master, China indiba deep fever master manufacturers, factory

Send Inquiry