XERF Face Shaper
video

XERF Face Shaper

World’s First Dual-Frequency Monopolar RF Technology: Utilizes a synergistic 6.78 MHz + 2 MHz dual-frequency approach to deliver layered heating down to the SMAS fascia. This overcomes the limitations of traditional monopolar RF, which typically targets only the superficial dermis, with safety and efficacy validated by histological evidence in SCI-indexed publications.
Comprehensive Multi-Layer Tightening, Lifting, and Skin Rejuvenation: Simultaneously achieves superficial skin rejuvenation (pore refinement and brightening), mid-layer firming (soft tissue tightening), and deep-layer lifting (jawline definition and double-chin reduction), all while preserving facial volume to avoid a sunken or gaunt appearance.
Painless, Non-Invasive, and Zero Downtime: Combines segmented pulses with synchronous liquid nitrogen cooling to maintain epidermal temperatures below 45°C, eliminating the need for anesthesia. A large, web-patterned probe ensures uniform energy delivery with no risk of burns; makeup can be applied immediately after treatment, and it is suitable even for sensitive skin.
Send Inquiry

Description

Technical Parameters

Product Overview
The Xerf Face Shaper delivers dual-unipolar radiofrequency at 6.78 MHz and 2 MHz simultaneously. The higher frequency tightens the dermis, refining pores and fine lines. The lower frequency reaches the SMAS layer, lifting sagging tissue without needles or surgery. A 30 mm spider-web electrode distributes energy evenly, avoiding hot spots, while synchronized liquid nitrogen cooling keeps the epidermis under 45°C. No topical anesthetic is required. One 600-shot protocol deposits 60 to 80 kJ into the target planes, triggering immediate collagen contraction and progressive remodeling that continues for six months. Published histology confirms collagen thickening at the SMAS-fascia interface.

2684-XERF1

Key Advantages

Dual-unipolar RF penetrates to the SMAS for a structural lift, not just surface tightening.

Three depth settings (Shallow, Middle, Deep) treat skin, soft tissue, and fascia in one pass without hollowing.

Integrated cryogen cooling fires with every pulse. Treatment is comfortable without numbing cream.

The 30 mm Effector 60 tip with a spider-net electrode pattern eliminates edge burns and post-treatment indentations.

SCI-journal histology supports the mechanism - real collagen remodeling, not marketing language.

Zero recovery time. Patients apply makeup immediately after the session.

 

Technical Specifications

Parameter Detail
RF Configuration Dual-unipolar, 6.78 MHz + 2 MHz
Treatment Tip Effector 60, 30 mm, spider-web electrode
Depth Selection Shallow, Middle, Deep
Pulse Modulation Wave Fit variable pulse (up to 12 sub-pulses)
Cooling Per-pulse liquid nitrogen synchronized jet
Epidermal Temperature Control Remains below 45°C
Standard Energy per Session 60–80 kJ (600 shots)
Power Supply 100–240 V AC, 50/60 Hz
Certifications ISO 13485, CE, FDA
Warranty 2 years

2684-XERF4

2684-XERF6

2684-XERF7

Ideal Settings

Medical Aesthetics & Dermatology Clinics: Anchor treatment for grade I–II skin laxity, jawline contouring, and periorbital tightening without injectables.

Plastic Surgery Practices: Pre-surgical skin conditioning and long-term maintenance for patients who are not yet ready for a facelift, or post-surgical maintenance.

Anti-Aging & Wellness Centers: Attract the 35–55 demographic seeking measurable lifting without social downtime.

Luxury Day Spas With a Clinical Edge: Add a high-ticket device service that sits above standard facials and complements microneedling or injectable programs.

Multi-Site Chains: Standardize outcomes across locations with a protocol-driven interface and identical energy delivery specifications.

 

Treatment Comparison

Standardized clinical photography and 3D volume analysis are used to document progress. The following examples reflect typical outcomes when a 600-shot, full-face protocol is applied over three sessions at four-week intervals.

Case A: 42-year-old female, primary concern lower face laxity and marionette lines.
Baseline photos showed blunting of the cervicomental angle and early jowling. Immediately after the first session, the jawline appeared crisper due to collagen contraction. At the three-month mark, 3D volumetric analysis measured a 2.1 mm elevation of the oral commissure and a 14 percent reduction in submental fullness. The nasolabial folds appeared shallower without any filler.

Case B: 38-year-old male, periorbital and forehead skin crepiness.
After two sessions, the under-eye skin showed visibly less redundancy on lateral tension views. The patient reported that colleagues commented on a "rested" appearance without being able to identify a procedure.

Case C: 55-year-old female, post-weight loss facial deflation.
A combined shallow and deep protocol preserved cheek volume while lifting the midface. The deep 2 MHz channel tightened the SMAS without dissolving fat, avoiding the sunken look that can accompany aggressive thermal treatments. At six-month follow-up, midface volumetric loss had actually reversed by 1.8 percent compared to pre-treatment baseline, attributable to new collagen deposition.

 

Practitioner Feedback

"We introduced the Xerf Face Shaper into our London clinic twelve months ago as an alternative for patients who refuse needles. The integration of cryogen cooling with every pulse means we can treat the full face, including the eyelids, in thirty minutes without topical anesthetic. The published histology gave our medical board confidence, and patients appreciate that the data exists in a journal, not a brochure."
- Dr. Helena V., Medical Director, London

"The spider-net electrode was the feature that sold me. I have used other monopolar devices that left linear indentations along the jawline. With the Xerf Face Shaper, the energy spreads so evenly that I can treat patients with very thin facial fat compartments without hesitation. The jawline definition we achieve after three sessions rivals what I used to see only with thread lifts."
- Dr. Marco S., Aesthetic Physician, Milan

"Our clinic chain in Singapore added the device as a premium facial tier. The zero-downtime claim holds up. We treat clients during lunch breaks, and they return to work with no redness. The treatment has become our strongest referral generator."
- Alicia T., Group Aesthetics Manager, Singapore

2684-XERF8

2684-XERF9

2684-XERF11

Manufacturing & Certifications

Weifang Benomi Electronic Technology Co., Ltd., headquartered in Weifang, China, has been engineering professional aesthetic systems for over 18 years. The company operates ISO-classified dust-free production workshops where every Xerf Face Shaper console is assembled and calibrated. Negative-ion air purification protects the RF circuitry and cryogen delivery components during manufacture.

The device holds ISO 13485 certification for medical device quality management, CE marking for the European Union, and FDA clearance for the United States. Benomi's supply chain relies on long-term component partners to ensure batch-to-batch uniformity. Every unit undergoes a full-power burn-in test and a cooling-system verification before packing, and a video of the operational test is shared with the buyer prior to dispatch.

 

Wholesale Policies

MOQ: One evaluation unit available. Wholesale pricing from five units.

OEM/ODM: Custom branding on console, tip, and interface. Free logo design included.

Lead Times: Sample units ship within 7 business days. Branded orders ship in 7 to 18 business days.

Warranty: 2-year comprehensive warranty with 24-hour after-sales support.

Training: Remote onboarding session and video library provided with the first order.

2661--2

2661-

Frequently Asked Questions

Does the treatment hurt?
No. The cryogen spray cools the skin surface with every pulse. Patients feel a cool touch and mild deep warmth. No numbing cream is needed, even around the eyes and lips.

How many sessions are typical?
A standard course is three sessions spaced four weeks apart. Annual maintenance sessions help preserve the lift.

Will it dissolve facial fat and cause a gaunt look?
No. The three-depth control allows deep SMAS tightening without overheating superficial fat. The spider-net electrode prevents concentrated edge-heating that can lead to localized atrophy. Volume is preserved, and midface fullness may even increase due to collagen deposition.

Is there scientific proof that the energy reaches the SMAS?
Yes. An independent study published in the International Journal of Molecular Sciences documented collagen thickening at the SMAS-fascia interface after treatment with the dual-unipolar system.

How do I request a quotation or a sample?
Complete the inquiry form on this page. Include your country and whether you need a sample unit, a wholesale order, or OEM branding. A product specialist will reply within one business day with a tailored proposal and current lead time. Your contact information remains confidential.

Hot Tags: xerf face shaper, China xerf face shaper manufacturers, factory

Send Inquiry