Endolaser Lipolysis
Multi-functional in one: Integrates more than ten functions including lipolysis and body sculpting, blood vessel removal, fungal treatment, anti-inflammatory skin tightening, etc.
Safe and precise: 1470nm acts superficially with no surrounding damage, 980nm provides excellent hemostasis, and 635nm provides anti-inflammatory effects without the need for foot pedals, ensuring safe and controllable treatment.
Description
Technical Parameters
What This Machine Is and How It Works
A lot of clinics buy one laser for fat reduction, a separate device for veins, and sometimes a third gadget for skin healing. The Endolaser Lipolysis platform from Benomi puts all three jobs into one compact box. It fires three distinct wavelengths-980 nm, 1470 nm, and 635 nm-through a single optical fibre that plugs into an SMA‑905 port on the front panel. You pick the wavelength pair or single wavelength that matches the job, and the beam travels down a 3‑metre glass fibre to whatever micro‑cannula or handpiece you have fitted.
When you're working on fat, the real magic sits at 1470 nm. Water absorbs this wavelength like a sponge. Since adipocytes and the fluid around them are mostly water, the energy stays right at the fibre tip, liquefying fat cells in a shallow, precise pocket. There's very little heat spread sideways-maybe a millimetre or two-so nerves and blood vessels sitting nearby stay cool.
At the same time, the 980 nm beam does two complementary things. It dives deeper, pushing roughly 16 mm into the hypodermis, and it grabs onto haemoglobin. That means as you move the cannula through fatty tissue, any tiny vessels that get nicked are instantly coagulated. Patients walk out with less bruising, and the fat emulsification is more uniform than you'd get with 980 nm alone.
The 635 nm red light is a completely different animal. It doesn't burn or cut anything. Instead, it kicks off photobiomodulation-a fancy word for saying that light energy wakes up the mitochondria inside cells. Cytochrome c oxidase soaks up that red light and starts producing more ATP. In practical terms, that calms inflammation, speeds up healing, and boosts local blood flow. The best part? This mode doesn't need the foot pedal. You set the intensity level on the 12.1‑inch touchscreen, and the machine delivers steady red light for as long as you want. That's great for treating a wide patch of eczema, soothing a freshly treated lipolysis area, or working on nail fungus without having to stand on a pedal.

What Stands Out in Daily Practice
One fibre, three different jobs. Lipolysis, vascular work, and photobiomodulation all come out of the same port. No swapping consoles or recalibrating between clients. You just choose the right setting on the screen and get to work.
1470 nm keeps the heat where it belongs. High water absorption means the laser energy only travels a short distance before it gets soaked up. That makes it safer to treat near delicate structures-nerves, arteries, the underside of the dermis-because the thermal damage is tight and predictable.
980 nm adds depth and haemostasis. While the 1470 nm handles the surface fat, the 980 nm reaches the deeper pockets and seals off small vessels. Together they produce a cleaner emulsification with noticeably less post‑operative bleeding.
635 nm anti‑inflammatory mode works without the pedal. Set the gear, press start, and the red light stays on continuously. Treat a large eczema plaque, a wound, or run a post‑lipolysis calming pass without having to keep your foot pressed down.
The whole system travels in a flight case. At 8 kg net, you can carry it from room to room, toss it in the boot of a car, or ship it to a second location. The flight case is 46 × 44 × 34 cm and everything fits inside-fibre, goggles, cannulas, foot pedal, manual.
Fibre core size is your choice. 200 μm for very fine work, 400 μm for most facial and vascular cases, 600 μm for standard body lipolysis, and 800 μm when you want to move through a large volume of fat quickly.
Touchscreen is clear and responsive. 12.1 inches, with straightforward controls for pulse width (15–60 ms), frequency (1–9 Hz), and mode switching. Language support is OEM customisable.
Technical Specifications
| Specification | Detail |
|---|---|
| Wavelengths | 980 nm (30 W), 1470 nm (3 W), 635 nm (12 adjustable levels) |
| Output type | Fibre‑optic coupling, SMA‑905 port |
| Fibre core options | 200 μm, 400 μm, 600 μm, 800 μm |
| Fibre length | 3 metres |
| Operating modes | Pulse, Continuous Wave |
| Pulse width | 15–60 ms |
| Frequency | 1–9 Hz |
| Aiming beam | 650 nm (red) |
| Control panel | 12.1‑inch colour touchscreen |
| Cooling | Air |
| Power input | AC 100–240 V, 50/60 Hz |
| Net weight | 8 kg |
| Gross weight (with flight case) | 13 kg |
| Main unit dimensions | 380 × 370 × 260 mm |
| Flight case dimensions | 460 × 440 × 340 mm |
| Safety glasses | Green (980/1470 nm), Blue (635 nm) |
| Included | Eye mask, handle and cannula set, foot pedal, manual, storage rod |
| Warranty | 2 years |



Where You'll See It Being Used
Aesthetic and cosmetic surgery clinics for chin, abdomen, flank, arm, and knee lipolysis. Also used for endovenous laser treatment (EVL) of small varicosities.
Dermatology offices that treat spider veins, nail fungus, eczema, herpes, and acne inflammation. The 635 nm mode gets used daily in many practices.
Medical spas that want one device that can handle non‑surgical fat reduction and also deliver anti‑aging and anti‑inflammatory red light sessions.
Physiotherapy and pain clinics where 635 nm photobiomodulation is applied to sore joints, stiff muscles, or slow‑healing soft‑tissue injuries.
Podiatry centres using the red light mode for onychomycosis-no oral medication, no pain, just steady low‑level light through the nail plate.
What Improvement Looks Like
| Procedure | Baseline | After a Standard Protocol |
|---|---|---|
| Laser lipolysis (abdomen, chin) | Pinchable fat pockets that don't shift with diet. | Gradual volume loss over 4–12 weeks. Less bruising than single‑wavelength lasers. |
| Vascular lesions (spider veins) | Red‑purple telangiectasias on legs or face. | Vessels collapse and fade after 1–2 sessions. Haemoglobin absorption helps seal the walls. |
| Onychomycosis | Thickened, discoloured nail. | Clear nail growth from the base after 4–6 red light sessions. No heat, no discomfort. |
| Eczema or herpes patches | Inflamed, itchy skin with active lesions. | Redness and itching reduce within 24–48 hours of 635 nm application. |
| Post‑lipolysis recovery | Erythema and mild swelling around the treated area. | Faster calming when 635 nm is applied right after the procedure. |
Individual results depend on age, health, and how closely the session schedule is followed. Lipolysis typically needs 1–3 sessions; nail fungus and inflammatory skin conditions usually take 6–10 sessions.
Real Feedback From Practitioners
Aesthetic surgeon, Barcelona – "I do submental lipolysis with the 1470 nm setting because I can see exactly where the energy is going. There's no charring outside the target layer. With 980 nm added, the bleeding is almost nothing. The 635 nm mode is my standard post‑treatment step-patients say their skin feels calmer the next day."
Dermatologist, Athens – "I ordered this laser mainly for nail fungus and eczema. Not having a foot pedal on the red light mode makes life so much easier. I position the fibre, set the level, and let it run while I write notes or talk to the patient. The fibre length is generous-I can move around the treatment couch without pulling anything."
Clinic owner, Dubai – "We needed a laser that could travel between our two branches. The flight case is robust, setup takes two minutes, and the interface is simple enough that my nurse can run the 635 nm part while I handle the lipolysis patients. It's made our mobile service much more professional."




Who Builds It – Benomi
Weifang Benomi Electronic Technology Co., Ltd. has been designing and manufacturing aesthetic and medical laser systems for over 18 years from its facility in Weifang, China. Production takes place in a dust‑free environment-critical for keeping optical fibres and diode bars clean and free of contamination.
Benomi offers free OEM/ODM logo design on the console, the start‑up screen, and the packaging. Language packs can be customised for different markets. The quality system follows ISO 13485, and the product holds CE and FDA certifications. Every machine is backed by a 2‑year warranty and 24‑hour technical support. Buyers receive a pre‑shipment testing video before delivery.
Ordering, Customisation & Delivery
MOQ – 1 unit. A sample machine for clinic evaluation can be arranged.
Branding – Free logo on the screen interface, device body, and packaging.
Customisation – Language packs, private‑label packaging, fibre core size selection.
Lead times – Standard orders ship in 3–5 business days. Custom‑branded units take 7–15 business days.
Shipping – Air express (DHL, FedEx, UPS) or sea freight, packed in the included flight case.


Common Questions
Do I have to manually switch between 1470 nm and 980 nm during lipolysis?
No. The lipolysis mode fires both wavelengths at the same time by default. 1470 nm handles the shallow, precise fat disruption; 980 nm adds depth and haemostasis. You just adjust the energy and pulse settings.
Why would I use the 635 nm anti‑inflammatory mode without the pedal?
Because it frees your hands. Set the gear on the screen, and the red light stays on continuously. This is especially useful when treating large eczema patches, healing wounds, or soothing a large area after lipolysis.
What fibre core size should I choose?
For body and submental lipolysis, 600 μm is the most common. For delicate vascular work or smaller areas, 400 μm gives more precision. Use 200 μm for very fine work and 800 μm when you want to emulsify a large volume quickly.
Will the nail fungus treatment hurt?
No. The 635 nm red light is non‑thermal. Most people feel nothing, or maybe a very mild warmth. The light passes through the nail plate without damaging the nail bed.
What eye protection is required?
Green glasses for the 980 nm and 1470 nm wavelengths. Blue glasses for the 635 nm red light. Everyone in the treatment room-including the patient-must wear the correct glasses. An eye mask is supplied for patients who can't wear glasses during facial work.
Hot Tags: endolaser lipolysis, China endolaser lipolysis manufacturers, factory
Previous
No InformationSend Inquiry














