Candela Hair Removal
Multi-mode cooling and flexible adjustment: A triple cooling system (DCD + air + water) combined with adjustable spot size and pulse width ensures comfortable and precise operation.
High-efficiency and durable design: Imported fiber optic transmission and infrared aiming beam ensure stable energy, precise positioning, and durable, reliable equipment.
Description
Technical Parameters
Product Introduction: Core Technology & Functionality
The Candela system is an alexandrite laser platform designed for professional hair removal, treatment of pigmented and vascular lesions, and tattoo removal. It combines dual-wavelength technology with an integrated cooling system to deliver energy to target tissues while minimizing discomfort.
Core Technology
Dual-Wavelength Configuration
755 nm (Alexandrite): This wavelength has high absorption in melanin, making it effective for hair removal in patients with light to olive skin tones. It also treats pigmented lesions such as freckles, age spots, and melasma.
1064 nm (Nd:YAG): This longer wavelength penetrates more deeply and is used for darker skin types. It is also effective for treating deeper vascular lesions and certain tattoo inks, particularly blue and black.
Cooling System
The system uses a multi-stage cooling approach:
DCD (Dynamic Cooling Device): A cryogen spray is applied to the skin milliseconds before each laser pulse, cooling the epidermis to protect it from thermal injury.
Air cooling: Continuous airflow helps maintain patient comfort during treatment.
Water cooling: Internal water circulation manages handpiece temperature for consistent performance.
Adjustable Parameters
Spot size: Adjustable from 6 mm to 24 mm in diameter, allowing practitioners to select the appropriate coverage area for different treatment sites.
Pulse duration: Adjustable from 0.25 ms to 100 ms, enabling customization for different tissue types and lesion characteristics.
Energy Output
755 nm: Up to 60 J
1064 nm: Up to 110 J
Additional Features
Fiber-optic energy delivery: The system uses imported optical fibers for stable energy transmission.
Infrared aiming beam: A visible aiming beam helps with precise placement of each pulse.
Safety indicators: Operational safeguards help ensure consistent treatment delivery.

Key Advantages
Dual-wavelength flexibility: One platform handles hair removal across a range of skin types (755 nm for lighter skin, 1064 nm for darker skin) as well as pigmented and vascular lesions.
Adjustable spot size: The 6–24 mm range allows treatment of both small facial areas and larger body surfaces.
Multi-stage cooling: DCD spray, air cooling, and water circulation work together to reduce discomfort and protect the epidermis.
Permanent hair reduction: Clinical protocols typically achieve permanent hair reduction after a series of treatments.
Versatile applications: In addition to hair removal, the system is used for freckles, age spots, spider veins, and tattoo removal.
Precision targeting: The infrared aiming beam and adjustable pulse duration help direct energy to the intended target.
Durable construction: Closed water circulation and extensive cooling systems support consistent operation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Laser type | Alexandrite / Nd:YAG dual wavelength |
| Wavelengths | 755 nm (alexandrite), 1064 nm (Nd:YAG) |
| Spot size range | 6–24 mm diameter (adjustable) |
| Pulse duration range | 0.25–100 ms |
| Energy output | 755 nm: up to 60 J; 1064 nm: up to 110 J |
| Cooling system | DCD (cryogen spray) + air cooling + water circulation |
| Energy delivery | Imported optical fiber |
| Aiming beam | Infrared |
| Power supply | AC 100–240V, 50/60 Hz |
| Certifications | CE, ISO 13485; FDA registration in progress |
| Warranty | 2 years (main unit) |



Professional Application Scenarios
The Candela system is used in:
Medical aesthetic clinics: Primary applications include permanent hair reduction, treatment of pigmented lesions (freckles, age spots, melasma), and vascular lesions (spider veins, hemangiomas).
Dermatology practices: Management of pigmentation disorders and vascular conditions.
Plastic surgery centers: Pre- and post-operative skin preparation, adjunctive treatment for scar management.
Tattoo removal studios: Effective for blue and black tattoo inks using the 1064 nm wavelength.
Multi-location practices: Consistent performance across different sites.
Primary indications:
Permanent hair reduction (all body areas)
Pigmented lesions (freckles, age spots, melasma)
Vascular lesions (spider veins, hemangiomas)
Tattoo removal (blue and black inks)
Treatment Outcomes: Expected Results
| Indication | Typical Sessions | Notes |
|---|---|---|
| Hair removal | 4–6 sessions | Sessions spaced 4–8 weeks apart; results vary with hair color and skin type |
| Pigmented lesions | 1–3 sessions | Freckles and age spots often respond within 1–2 sessions; melasma may require more |
| Vascular lesions | 2–4 sessions | Spider veins typically fade after 2–3 sessions |
| Tattoo removal | 4–8 sessions | Black and blue inks respond best; complete removal depends on ink density and depth |
Timeline for hair removal:
Initial reduction: Visible after 2–3 sessions
Optimal results: After 4–6 sessions, with ongoing improvement over several months
Maintenance: Occasional touch-up sessions may be needed
Results vary based on individual factors including skin type, lesion characteristics, and treatment intervals.
Professional Feedback
Practitioners using alexandrite laser systems have reported:
*The dual-wavelength capability allows us to treat a broader range of patients without switching machines. For hair removal, we use the 755 nm wavelength for lighter skin and the 1064 nm for darker skin types. The adjustable spot size is useful-we can cover large areas like legs quickly, then switch to a smaller spot for precision work on the upper lip or chin.* - Dr. Elena Vasquez, Medical Director, Miami Aesthetics
The DCD cooling system makes a noticeable difference in patient comfort. The cryogen spray is timed just before each pulse, so patients feel a brief cool sensation rather than heat. We have found this especially helpful for sensitive areas like the bikini line and underarms. - Dr. Marcus Webb, Aesthetic Medicine Specialist, London
*For tattoo removal, the 1064 nm wavelength is our go-to for black and blue inks. We typically see good fragmentation after 3–4 sessions, though complete removal can take longer depending on the tattoo's age and ink depth.* - James Chen, Tattoo Removal Specialist, Singapore




Manufacturer Credentials: Benomi Electronics
Weifang Benomi Electronic Technology Co., Ltd. has specialized in the research, development, and manufacturing of professional aesthetic equipment for over 18 years. Headquartered in Weifang, China, the company operates ISO-certified cleanroom facilities where assembly takes place under controlled conditions.
Quality Assurance:
Manufacturing environment: Dust-free cleanrooms help maintain component integrity for high-precision electronic systems.
Regulatory compliance: Products carry CE certification and are manufactured under ISO 13485 quality management. FDA registration is in progress for applicable markets.
Pre-delivery testing: Each unit undergoes functional testing before shipment; test records are available upon request.
Component sourcing: Critical components, including laser sources and optical fibers, are sourced from established suppliers.
Post-sale support: 2-year warranty on the main unit; 24/7 multilingual technical support available.
Wholesale and Distribution Information
Minimum order quantity: 1 unit for qualified buyers; volume-based pricing available.
Customization options: Custom logo placement on device and home screen; interface language localization; handpiece branding.
Lead times: Standard orders ship within 5–7 business days; customized orders require 15–30 days.
Shipping: Worldwide delivery via air freight (DHL, UPS, FedEx, 3–10 days) or sea freight for volume orders; tracking provided.
Packaging: Secure packaging with foam inserts for transport protection.
Partner support: Installation guidance, remote training, marketing materials, and ongoing technical consultation included.


Frequently Asked Questions
Q: What is the difference between the 755 nm and 1064 nm wavelengths?
A: The 755 nm wavelength (alexandrite) has high absorption in melanin and is commonly used for hair removal in patients with light to olive skin. It is also effective for pigmented lesions such as freckles and age spots. The 1064 nm wavelength (Nd:YAG) penetrates more deeply and is used for darker skin types, deeper vascular lesions, and tattoo removal (blue and black inks).
Q: How does the cooling system work?
A: The system uses three cooling methods. DCD (Dynamic Cooling Device) sprays cryogen onto the skin milliseconds before each laser pulse, protecting the epidermis. Air cooling provides continuous airflow during treatment. Water circulation manages handpiece temperature for consistent performance.
Q: Is the treatment painful?
A: Patients typically describe the sensation as a mild snap followed by a cool spray. The DCD cooling system helps reduce discomfort. Most patients tolerate treatments well without anesthesia, though topical numbing may be used for sensitive areas.
Q: How many sessions are needed for hair removal?
A: Most patients require 4–6 sessions spaced 4–8 weeks apart. Hair grows in cycles, and only follicles in the active growth phase (anagen) respond to laser treatment. Results vary with hair color, skin type, and hormonal factors.
Q: Can this laser be used on darker skin?
A: Yes. The 1064 nm wavelength is specifically designed for darker skin types (Fitzpatrick IV–VI). The longer wavelength penetrates more deeply and has less melanin absorption in the epidermis, reducing the risk of pigmentation changes.
Q: What maintenance does the system require?
A: Keep handpiece optics clean with a soft, lint-free cloth. The closed water circulation system requires periodic checks to ensure proper levels. The laser source is rated for extended use and does not require routine replacement.
Q: Do you provide training?
A: Yes. Basic operational training is included with purchase, covering setup, parameter selection, and safety protocols. Online and video training resources are available.
Q: What certifications does the machine have?
A: The system is CE certified and manufactured under ISO 13485 quality management. FDA registration is in progress for applicable markets.
Contact
For technical specifications, pricing inquiries, or to arrange a product demonstration, please contact Benomi's commercial office. Typical response time is 24–48 hours.
Hot Tags: candela hair removal, China candela hair removal manufacturers, factory